title: Equipment Requirements
slug: scenario/equipment-requirements
docTags: 
createdAt: 2024-10-03T13:07:11.802Z
---

# Camera 

CinCraft Scenario supports all major cinema and broadcast cameras, but the following requirements are needed: 

- The Origin requires an HD signal (up to 1080p60).  Higher resolution camera signals are not supported and must be down converted before being connected to the Origin 
- Timecode is not required for tracking but is **required&#x20;**&#x66;or the recording of tracking data. 
- Image stabilisation (camera or lens) is not supported and should be disabled for accurate tracking 
- Cameras that provide an SDI signal are strongly recommended.  HDMI outputs are not inherently supported but can be used if converted to SDI using a third-party converter (not provided) 

# Lens Support 

The following lenses are included with the Scenario software, these are either offered as Virtual Lens Packages (V.L.P.) Which require no calibration, or as templates or manually calibrated lenses which will require user input to achieve good results

:::ExpandableHeading
# VLP Lenses

VLP lenses require no calibration and allow for “plug and play” usage. 

### Free of charge 

ZEISS CP3 and CP3.XD 

ZEISS Supreme Prime and Supreme Prime Radiance 

ZEISS Nano Prime 

### Requires a license 

ZEISS CP2 

ZEISS Compact Zoom 

ZEISS SuperSpeed/HighSpeed 

ARRI/ZEISS Master Prime 

ARRI/ZEISS Ultra Prime 
:::

# Free Templates

Templates are provided free of charge and are manually calibrated lens files, they are not as accurate as VLP lenses and require the user to “refine” the lens file when it is added to a project 

:::ExpandableHeading
## Angenieux

### Optimo Prime: 

- 18 
- 21 
- 24
- 28
- 32 
- 40 
- 50 
- 60 
- 75 
- 100 
- 135 
- 200

### Optimo Zoom 

- 15-40 
- 17-80 
- 24-290 
- 28-340 
- 28-76 
- 37-102 
- 45-120 

### Optimo Ultra Compact

- 21-56mm

### EZ-1 

- 30-90 
- 45-135 

### EZ-2 

- 15-40 
- 22-60 

### EZ-3 

- 45-164 
- 68-250
:::

:::ExpandableHeading{isOpen="true"}
## Cooke

### S4 

- 12 
- 14 
- 16 
- 18 
- 21 
- 25 
- 27 
- 32 
- 40 
- 50 
- 65 
- 75 
- 100 
- 135 
- 150 
- 180 

### S7 

- 16 
- 18 
- 21 
- 25 
- 27 
- 32 
- 40 
- 50 
- 65 
- 75 
- 100 
- 135 
- 180 

### S8 

- 25 
- 32 
- 35 
- 40 
- 50 
- 75 
- 100 
- 135 

### Panchro Classic S35

- 18
- 25
- 32
- 50
- 65
- 75
- 100
- 135

### Panchro Classic FF

- 18
- 21
- 25
- 27
- 32
- 40
- 50
- 65 
- 75
- 100
- 135

### Varotal Zoom 

- 19-40
- 30-95 
- 85-215 
:::

:::ExpandableHeading
## ARRI

### Signature Prime 

- 12
- 15 
- 18 
- 21 
- 25 
- 29 
- 35 
- 40 
- 47 
- 58 
- 75 
- 95 
- 125 
- 150 
- 200 

### Signature Zoom 

- 16-32
- 24-75
- 45-135
- 65-300
:::

:::ExpandableHeading
## Canon

### Cine Servo

- 15-120mm
- 15-120 - 1.5x

### KJ 

- 20x8.2 

### CJ 

- 12ex4.3b 
- 14ex4.3b 
- 15ex4.3b 
- 17ex6.2b 
- 20ex7.8b 

### CN 

- CN-7x17 KAS 
- CN-E18-80 
- CN-E45-135 

### XJ 

- 22ex7.3b 

### HJ 

- 11ex4.7b 
- 14ex4.3b 
- 21ex7.5b 
- 22ex7.6b
:::

:::ExpandableHeading
## DZOFILM

### Pictor 

- 12-25 
- 20-55 
- 50-125 

### Catta 

- 18-35 
- 35-80 
- 70-135
:::

:::ExpandableHeading
## Fujinon

### UA 

- 13x4.5 
- 23x7.6 

### Premista 

- 19-45 
- 28-100 

### HA 

- 14x4.5 
- 18x5.5 
- 18x7.6 
- 23x7.6 

### Duvo 

- 24-300 
- 36-450 

### Cabrio 

- 14-35 
- 19-90 
- 20-120 

### MK

- 18-55

### ZA 

- 12x4.5
:::

:::ExpandableHeading
## LEITZ

### Zoom

- 25-75mm
- 55-125mm

### Prime

- 18
- 21
- 25
- 29
- 35
- 40
- 50
- 65
- 75
- 100
- 135
- 180

### Summicron - C

- 15
- 18
- 21
- 25
- 29
- 35
- 40
- 50
- 75
- 100
- 135

### Summilux-C 

- 16 
- 18 
- 21 
- 25 
- 29 
- 35 
- 40 
- 50 
- 65 
- 75 
- 100 
- 135
:::

:::ExpandableHeading
## Tribe 7

### Blackwing 7 

- 27 
- 37 
- 47 
- 57 
- 77
- 107
- 137
:::

# Manual Calibration

Any 3rd party spherical lens is supported in Scenario via manual calibration.

Please refer to the Manual Lens Calibration section for instructions on how to calibrate lenses

Lenses with cine gearing and physical end stops on the focus/zoom barrels are strongly recommended for manual calibration